Mounting wall hung boiler high on the wall Screwfix


Mounting wall hung boiler high on the wall Screwfix

Mounting wall hung boiler high on the wall Screwfix
  • Offshore price : $8,999.00 - $100,000.00
  • Minimum order quantity : 1 set
  • Supply Capacity : 10 units/month
  • Manufacturer/Brand : TOBO BOILER
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

  • Energy Kinetics System 2000 Replacement Parts

    Sep 13, 2021 · Energy Kinetics System 2000 Replacement Parts. Getting a bit of a runaround and hoping this forum will provide some assistance. I am fully capable of repairing my boiler (and a great many other things). However, Energy Kinetics apparently will not sell the parts I need. They tell me that only a licensed plumber can contact them to purchase the Get Price

  • Tekmar 260 outdoor reset with Energy Kinetics System 2000?

    Jul 05, 2009 · I recently replaced a 50 year old gas boiler + gas DHW with EK-1 System 2000 + indirect DWH. Is it possible to gain further efficiency by using an outdoor reset such as the Tekmar 260? I saw the Tekmar unit on Ask This Old House on TV. They stated that the 180 degree boiler limit is designed for the coldest winter days. It is inefficient to operate the boiler to this …Get Price

  • Hot Water Manual - Energy Kinetics

    Energy Kinetics offers several ways of making hot water. This manual covers those several ways, one way at a time. You may go directly to the section that applies to your choice of making hot water. We then finish with a plate heat exchanger trouble shooting section. 1. Plate heat exchanger piped into the boiler bypass line. 2.Get Price

  • Power Stealing vs. Hardwired Thermostats, System 2000

    I have an Energy Kinetics System 2000 boiler that was installed last spring. I have been using the same 2 thermostats that were installed with my old boiler. One is a simple bimetallic coil spring unit and the other is an electronic unit with limited programmability. The …Get Price

  • ENERGY KINETICS SYSTEM 2000 TESTIMONIALS

    I want to express my gratitude to you and your company regarding my Energy Kinetics boiler.. installed our new boiler in the Fall of 2008 in the basement of my ranch style house. We have seen a large reduction in our oil consumption as a result of the new unit and its efficiency.Get Price

  • Heating System Boiler Limit Controls & Strap-On Aquastats

    We just bought a house with an old oil-fired boiler with a single zone and single circulator pump. It has OLD strap-on limit controls, both on the hot side just above the boiler. One limit control is the high temperature shut-off for the burner, the other controls the circulation pump. The boiler is currently set to 180, which seems right to me.Get Price

  • Boiler upgrade recommendation? - GreenBuildingAdvisor

    Jul 01, 2015 · I'm currently looking to upgrade my old boiler as it developed a small crack and is leaking. My current boiler is a P-468U-wt (151,000 btu/hr) Weil-McClain oil-fired boiler with a 40-gallon hot water holding tank. I'm getting two different suggestions from two of my plumbers and would love some input on their recommendations. One recommends replacing it with an …Get Price

  • Energy Kinetics 2000 EK1 Frontier - Skylands Energy

    Problem: The Searles had an old and outdated Burnham hot water boiler in their home.It had a large crack and could no longer provide a comfortable level of heat in an energy-efficient manner. Solution: Skylands Energy installed an Energy Kinetics 2000 Frontier EK-1 with a hot water storage tank in their Califon, NJ home.Get Price

  • Energy Kinetics 2000 - Hot water call cycling

    Jan 24, 2011 · Energy Kinetics 2000 - Hot water call cycling. I'm having some troubles with my EK 2000 system during hot water calls. During/after running a bunch of hot water (e.g. shower) the System Manager calls for hot water just like it should and the boiler fires up. The boiler goes from cold to 140 and then the circulator for the hot water tank starts up.Get Price

  • Energy Kinetics System 2000? - RIDGID Forum | Plumbing

    Mar 17, 2011 · Re: Energy Kinetics System 2000? Hi, I am new to this forum and wanted to ask a question about my system 2000 boiler. I have had it for 4 years now and it saves me money. The only problem I am having is that for the past few days now I have to keep reseting my boiler to get my hot water. Just yesterday i had to do it 4 times.Get Price

  • HVAC Case Studies, Heating & Cooling - Skylands Energy

    They still had a cast iron boiler that was approximately 30 years old. When the Garcias purchased their home 30 years ago, the boiler system came with the house. We removed their old boiler and replaced it with a System 2000 Energy Kinetics-1 Boiler and a 40 Gallon Indirect Water Heater. We did all of the necessary modifications of all the Get Price

  • Energy Kinetics System 2000? - RIDGID Forum | Plumbing

    Mar 03, 2009 · Re: Energy Kinetics System 2000? Ha. Funny to see this thread still alive. I had the EK 2000 installed in May 2006 to replace the original boiler to the house (1955). We lived for two years with the old boiler, now two years with the EK 2000. I …Get Price

  • FAQ | Energy Kinetics

    Solution: The Garcias contacted Skylands Energy because they knew that they needed a new heating system. We removed their old boiler and replaced it with a System 2000 Energy Kinetics-1 Boiler and a 40 Gallon Indirect Water Heater. We did all of the necessary modifications of all the piping & wiring. Learn More About Energy Kinetics BoilersGet Price

  • Energy Kinetics system 2000/ gasification boiler

    Feb 24, 2014 · Feb 23, 2014. #1. Hello, This fall I installed a Econoburn 200k boiler. My heating prior to that installation was comprised of a energy kinetics system 2000 oil boiler with super store hot water. The boiler heated one zone of baseboard and one zone of radiant panels. I added a zone on in-slab radiant heat in the new kitchen addition at the same Get Price

  • Work We've done in Richmond,VT - vtenergy.com

    Dec 09, 2011 · Energy Kinetics EK1 Energy Kinetics System 2000 Oil Boiler. Registration for Josh in Richmond, VT Liming. Installation of radiant heat zone in kitchen. There was a great deal of work that needed to be done including removing the old behemoth. We are still adjusting to the triangle tube system but it is working well.Get Price

  • How to prevent your boiler from - Ted's Energy Tips

    Mar 24, 2011 · We installed a System 2000 last January to replace the aging Weil-McLean boiler in our 27 year old house. I was sold on the energy saving theory behind System 2000, along with a number of positive reviews I read on various heating forums.Get Price

  • Loving our new Energy Kinetics System 2000and a

    System 2000: Combined Heat and Hot Water Boiler [High Get Price

  • Energy kinetics system 2000 parts list

    Energy kinetics system 2000 parts list We were the 1st company in New Hampshire to sell and install System 2000. I still run across units I installed over 20 years ago when the jacket used to be grey. Still running just fine. It is a good boiler indeed sigpic All Some of today's heating systems are very similar to those installed generations ago.Get Price

  • Power Stealing vs. Hardwired Thermostats, System 2000

    I have an Energy Kinetics System 2000 boiler that was installed last spring. I have been using the same 2 thermostats that were installed with my old boiler. One is a simple bimetallic coil spring unit and the other is an electronic unit with limited programmability. The …Get Price

  • EK system 2000 - internal plate heat exchanger leak

    Oct 15, 2013 · The background: We have a System 2000 boiler which was installed in 2007. One problem I've been having with it because of our hard water is the plate heat exchanger clogging. I purchased an extra one, and have to swap every 8 months, and clean out the old one with Sizzle.Get Price

  • System 2000 EK1 OIL HOT WATER SYSTEM - DoItYourself.com

    Nov 27, 2012 · Boilers - Home Heating Steam and Hot Water Systems - System 2000 EK1 OIL HOT WATER SYSTEM - I have a system 2000 oil hot water system that was installed in 1996. I bought the house in 2000 so I have had the system for 12 years. It is a very efficient system. It has a unhooked up 50 gal water heater that serves as aGet Price

  • [Case Study] Oil Boiler Upgrade & Oil Tank Insallation in

    Jun 04, 2018 · The Energy Kinetics System 2000 boilers, like the EK1F unit we installed in this home are incredibly efficient units. They can cut home heating bills up to 40% because of their clean-burning, whisper quiet operation. With heat and hot water accounting for up to 75% of most homes energy use, this increased efficiency will really help save the Get Price

  • Help: New Energy Kinetics System 2000 EK1 OR peerless WBV3

    Jan 26, 2021 · I'm looking for help to decide between installing a new Energy Kinetics System 2000 EK1 or peerless WBV3-105-W Both boilers are offered with indirect water heaters. I live in 3200 sq.ft colonial house with 148 feet of baseboard in New Jersey. I currently have 3 zones, but considering getting the 4th zone in the future for my basement.Get Price

  • High Efficiency Residential Oil Boilers | Energy Kinetics

    Conventional Oil Boilers vs. Energy Kinetics Oil Boilers. As seen in this thermal image, heavy cast iron boilers finish hot at 160°F to 200°F—even in the summer—causing up to 40% annual energy losses. Energy Kinetics boilers have over 90 lbs. of insulation and jacketing, virtually eliminating all losses. Common boiler controls and outdoor Get Price

  • How much oil have you burned so far | Hearth.com Forums Home

    Feb 21, 2013 · I still have no insert or stove and it looks like 2015 will be my first wood burning year. Anyway, we use oil for both water and heat. I have a two thousand square foot house with a two year old Energy Kinetics System 2000 boiler. I have gone through 435 gallons so far and I am down to a quarter tank. We are in central New Jersey "Shore" area.Get Price

  • System 2000 Frontier® Boilers - Energy Kinetics

    The Energy Kinetics boiler design combines heat and hot water into one unit. Energy Kinetics' hot water tank uses a high-performance plate heat exchanger to heat the tank from the top down. This allows heat remaining in the boiler to be …Get Price

  • Energy Kinetics System 2000 - Worth the money? : HVAC

    Energy Kinetics System 2000 - Worth the money? If you read my previous posts, you will see that we have been having heating system problems lately - 2 shutdowns in 2 days. We have known since moving in 14 months ago that our current oil-fired boiler had minimal life left, 5 years if we were very lucky.Get Price

  • I have Energy Kinetics System 2000 boiler model EK1

    Nov 11, 2018 · I have an Energy Kinetics System 2000 EK-1 boiler equipped with a plate heat exchanger to produce DHW. The Energy Manager has a 140 flashing code. Could this be caused by plugging of the plate heat ex … read moreGet Price

  • Energy Kinetics System 2000 hybrid Oilheat

    Energy Kinetics System 2000 hybrid Oilheat. Our fuel company is offering us two different systems to replace our failing oil burner. One is a Peerless model WBV-04-WPCO high effeciency cast iron boiler wtih a Beckett Flame Retention head oil burner at about $6K. The other system is the Energy Kinetics 2000, model EK-2, integrated heat and hot Get Price

  • Boiler Repair, Maintenance, Installations | Townsend Energy

    Energy Kinetics. Energy Kinetics' System 2000® boilers combine heat and hot water to maximize efficiency in all seasons. These systems offer virtually unlimited domestic hot water coupled with whisper quiet operation. With a System 2000, you can look forward upwards huge energy savings.Get Price

  • The Ugly TRUTH About Cast Iron Boilers - Energy Kinetics

    The Energy Kinetics' Warranty. If you want lower monthly fuel bills, plus a boiler that lasts and is backed by the industry's best lifetime warranty, give Energy Kinetics a call at 800-323-2066 or email us and put Energy Kinetics' steel boilers' proven track record to work heating your home or business and start saving today! Get Started!Get Price

  • steel vs. cast iron oil boiler opinions?

    Jan 22, 2010 · We have an energy efficient (by 1987 standards) 2,000 sq ft contemporary in NH with 2 zone baseboard hot water heat and tankless hot water coil. Our Burnham V-714T cast iron oil fired boiler is on its last legs (internal leaks), and our trusted oil supplier/HVAC installer has recommended either a steel New Yorker boiler or a more efficient cast iron Weil-McLain for …Get Price

  • Energy Kinetics HVAC age | Building Intelligence Center

    For proven reliability and performance The system 2000 saves more than other oil or gas boilers. JC Heating & Cooling has been providing Home Heating Oil, Sales and Service in Bucks County for over 40 years. For more information about oil fired hot water heating systems, Call 215-945-4833 or 215-493-7455Get Price

  • Which is Best: Lockinvar of Energy kinetics 2000?

    I have looked at Energy Kinetics 2000, that can accomodate cast iron radiators (hopefully well) and can simply be converted to an oil or gas boiler by simply changing the burner in it (does not include piping gas to furnace and chimney expenses. I recently received a quote for a Lockinvar * Knight gas boiler system which cannot be converted.Get Price

  • I have an Energy Kinetics system 2000 oil fired water boiler…

    Jan 02, 2009 · I have an Energy Kinetics system 2000 oil fired water boiler system ( model # XXXXX ) less than 2 years old. I have heat in the house but no hot water .. started (3) days ago and has slowy changed to completly cold water. Any helpfull ideas of what could be the problem.Get Price

  • Condensing boiler really worth it? - HVAC-Talk

    Dec 17, 2012 · And we're looking at the Energy Kinetics System 2000. Efficiency questions, akin to MassMax: A: E.K. (citing Brookhaven tests) says that AFUE, esp. when tied to water heating, is NOT a good measure, and that E.K. beats the best modulating condensing boilers by a …Get Price

  • Energy Kinetics Installation Expenses: What You Need To Know

    Can Energy Kinetics boilers like System 2000 run reliably on a generator? How much does System 2000 cost? How should I prepare for a visit with a heating professional? System 2000's Energy Manager Exceeds All 2012 Temperature Reset Requirements If I need a part for System 2000, how do I get it?Get Price

  • Energy Kinetics System 2000 Boiler - DoItYourself.com

    Oct 24, 2012 · We all have houses between 1500 and 2000 sq ft. Neighbor #1 has an old 1980 Weil-Mclain with a tankless coil. #2 has a Peerless WBV with an indirect from 2001. #3 has a Burnham V83 with a SuperStor indirect from 2000. #4 has a New Yorker with the tankless coil in 2004 when the house was built.Get Price

  • Energy Kinetics Boiler Reviews - Furnace Compare

    Jan 23, 2020 · Shawn. Garrison NY. Kefid16. "System 2000 has saved me a fortune on oil". 5.0 rating. Very Satisfied. I have had an Energy Kinetics Frontier System 2000 boiler in my home since I moved in fifteen years ago. After bad experiences with Weil McClain and Burnham boilers cast iron blocks leaking in my first home, I'm sure glad to have a rugged Get Price

  • I need to replace a 30 plus year old oil heat boiler. The

    Dec 02, 2010 · I need to replace a 30 plus year old oil heat boiler. The quotes I have received are for a Energy Kinetics System 2000,a Peerless WBV03-WPC or a Buderus G115WS/4. The quotes I have received are for a Energy Kinetics System 2000,a Peerless WBV03-WPC or …Get Price

  • Best Natural Gas Boiler? : HomeImprovement

    That said, we have been quoted on several natural gas boilers and have narrowed it down to the following: Energy Kinetics - EK1C Accel CS with indirect water heater or hot water storage tank. Navien NHB-110 with indirect water heater. Lochinvar Energy …Get Price

  • Energy Kinetics system 2000/ gasification boiler

    I also got one other company to come out on Wednesday but they didn't offer the EK systems. The non EK company came in at $4000 higher than the original quote for the same Buderus system. The company that did EK systems quoted a Buderus at $500 less than the original quote. The System 2000 was only $200 more than their Buderus quote.Get Price

  • Converting from oil to gas | DIY Home Improvement Forum

    Jan 08, 2018 · Hey all, so my oil tank has a leak and I'm using this opportunity to explore converting from oil to gas. My boiler and water heater is an Energy Kinetics System 2000, which is 9 years old (put in place by the previous owner of my house). It seems that I can save a lot of money over the long term by converting to gas.Get Price

  • I have a System 2000 Energy Kinetics hot water boiler by

    Jul 26, 2017 · Contact Energy Kinetics. Energy Kinetics. 800.323.2066 [email protected] 51 Molasses Hill Road, Lebanon, NJ 08833. Inspection Notes. This area has been reserved for any special considerations that inspectors or HVAC equipment owners should pay particular attention too.Get Price

  • I need to replace the electrodes on a Energy Kinetics EK-1

    Jul 22, 2014 · We have an old energy kinetics 2000 boiler that is still. we have an old energy kinetics 2000 boiler that is still going strong after about 30 years. we noticed a 'motorized valve' was leaking this year and rather than spending $500 to get it fixed, Get Price

Hot News

Hot News

Hot News